Circuit breaker AVM4NVU3-AVM4N

Circuit breaker AVM4NVU3-AVM4N

We sell of automatic circuit breakers ABM4HB, ABM4HB-T3, AVM4NV-U3, AV4N, AV4NV withdrawable version and AVM4N-U3, ABM4H, ABM4H-T3 stationary for 500V, 380V, 400 V - 400A, 300A, 250A, 200A, 150A, 120A, 500А, 600A. Automatic switches AVM4NV, AVM-4NV, ABM 4HB, ABM 4H, ABM4NM and AVM4N have been successfully operated for 55 years in substations of factories in Ukraine, Azerbaijan, Moldova, Georgia, Turkey, Bulgaria, Kazakhstan, Latvia, Estonia, Lithuania, Armenia, Albania, Uzbekistan, Vietnam, Mongolia, Montenegro, India, Macedonia, Poland, Romania, Czech Republic, Slovakia, Slovenia, Turkmenistan, Tajikistan, Kirghizia, Tajikistan as well as in other European countries and Asia. Selling automatic circuit breaker AV4NV, AV4NM, AVM 4NV-U3. Circuit breaker AVM type 400V 400A TU16-522.010-73, new best price! Warranty, Export, service, repair, spare parts. Sale the breaker AV4SN. Buy automatic switch ABM4H. Sell the automatic circuit breakers ABM4HB-Y3 - 400 A, 200A, 250 A, 300 A, 150 A, 120 A.

Technical description: AVM4N automatic circuit breakers are manufactured by electromagnetic releases and releases for tripping from overload. Automatic switches AVM4N 2 poles are made on a direct current. Automatic switches АВМ4Н 3х polar, are made on an alternating current. AVM4N-non-selective automatic switches (high-speed)

Automatic switches AVM4N are designed to conduct current in normal mode and protect against overloads of unacceptable duration, short circuits and unacceptable voltage drops, as well as infrequent, up to 20 times a day, operational disconnections of electrical circuits with a rated voltage of up to 660 V AC frequency 50 and 60 Hz and up to 440 VDC. AC automatic circuit breakers can also be used for protection and infrequent direct starts of asynchronous motors in the application category of AC-3. Circuit-breakers are produced by thermal and electromagnetic maximum releases, only with electromagnetic maximum current releases and without maximum current releases. The circuit breakers can be equipped with a minimum voltage release, an independent release, free contacts and an electromagnetic drive. Automatic are produced in a stationary version - front, rear and combined connection and in retractable design.

Technical characteristics of the switches:

1. Rated current 400A.

2. Number of poles 2; 3.

3. Rated currents of the releases from overload- up to 120, 150, 200, 300, 400A.

4. The setting for the initial pick-up current in the zone of the overload currents, a multiple of the rated current of the thermal release 1.25.

5. Settings for the current tripping of electromagnetic maximum current releases up to 4000A.

6. Rated operating short-circuit breaking capacity, kA: at a rated voltage of 380 V AC 25, at a nominal voltage of 660 V AC 19, at a nominal voltage of 440 VDC 50.

7. Wear resistance of circuit breakers - total number of cycles of VO 3000, number of VO cycles under load 1500.

8. Weight - up to 49 kg.