Circuit breaker AVM10SV, AVM10S, AVM10C
We sell of automatic circuit breakers AVM10SV-U3 withdrawable version and AVM10S-U3 stationary for 500V 1000A, 800A, 750A, 600A, 500A. Automatic switches AVM10S V, AVM 10S V, AV10S V, AVM-10S V, AVM-10SV and AVM10 SU3 1000 A, 700 A, 500 A, 600 A, 800 A. Export is possible. We manufacture the entire line of automatic switches of the AVM10 series, 500A - 1000A. It is profitable to buy in Ukraine automatic circuit breakers AVM10SV-U3 of withdrawable design and AVM10S-U3 stationary for voltage of electric circuits 380 V, 400V, 500V 50-60 Hz for rated current 800A, 1000A, 500A, 600A, 750 A, AC/DC - LLC RPE RIMK. Production of automatic circuit breakers AVM10SV, AV10SV, AVM-10C in Ukraine. We will send automatic circuit breakers AVM-10SV, AVM10S, AVM 10SV, AVM 10S, AVM-10SV, AVM-10S, AVM10SVU3, AVM10SM-U3 (shipborne), AVM 10SM, AVM10SU3, AV 10SV, AVM 10SV-U3, AVM 10SU3, AVM10S ~380V transport companies or self-pickup from the city of Kharkiv (Kharkov). To order the AVM10S and AVM10SV automatic switch for non-standard currents - RPE RIMK will fulfill any order. We produce all types of automatic switch AVM 800A, for any climate. Another name for this product is the AVM10S contactor and the AVM10SV contactor. Circuit breaker AVM type 400V 800A, 600A, 500A TU16-522.010-73. Automatic circuit breakers AVM10SV, AV10SV, AV10S and AVM10S have been successfully operated for 50 years in substations of factories in Ukraine, Turkey, Azerbaijan, Moldova, Kazakhstan, Latvia, Estonia, Lithuania, Armenia, Kyrgyzstan, Uzbekistan, Turkmenistan, Kyrgyzstan, Georgia, Bulgaria, Romania, Poland, Mongolia, Czech Republic, Montenegro, Slovakia, Slovenia, Serbia, Bosnia, Herzegovina, Tajikistan, as well as in other countries of Europe and Asia! Service, repair of AVM10SV and AVM10S. The cost of the AVM10SV breakers can be reduced when ordering in bulk. Buy, selling circuit breaker ABM10CB. Warranty, service, repair, spare parts
Technical description: AVM10 circuit breakers are manufactured by electromagnetic releases and releases for tripping from overload. Automatic switches AVM10 2-pole are made on a direct current. Automatic switches AVM10 3х polar, are made on an alternating current. AVM10С - selective circuit breakers (with a delay of operation on time). Automatic circuit breakers AVM10С are designed to conduct current in normal mode and protect against overloads of unacceptable duration, short circuits and unacceptable voltage drops, as well as for infrequent, up to 20 times a day, operational tripping of electrical circuits with a rated voltage of up to 660 V AC frequency 50 and 60 Hz and up to 440 VDC. AC automatic circuit breakers can also be used for protection and infrequent direct starts of asynchronous motors in the application category of AC-3. Circuit-breakers are produced by thermal and electromagnetic maximum releases, only with electromagnetic maximum current releases and without maximum current releases. The circuit breakers can be equipped with a minimum voltage release, an independent release, free contacts and an electromagnetic drive. Automatic are produced in a stationary version - front, rear and combined connection and in retractable design.
Technical characteristics of the switches:
1. The rated current is 1000A, 800A, 600A, 750A, 500A, 700A.
2. Number of poles 2; 3.
3. Rated currents of releases from overloads - up to 1000A.
4. Setting for the initial pick-up current in the zone of the overload currents, multiples of the rated current of the thermal trip unit 1.3.
5. Settings for the current of operation of electromagnetic maximum current releases up to 7000A.
6. Rated operating short-circuit breaking capacity, kA: at a rated voltage of 380 V AC 25, at a nominal voltage of 660 V AC 19, at a nominal voltage of 440 VDC 50.
7. Wear resistance of circuit breakers - total number of cycles of VO 3000, number of VO cycles under load 1500.
8. Weight - up to 50 kg.