AV2M20SV, AV2M20S automatic switch

AV2M20SV, AV2M20S automatic switch

We sell AB2M20SV-55-43-UHL3 automatic withdrawable circuit breakers and AB2M20S-55-43-UHL3 automatic circuit breakers stationary for 380V, 500V electrical networks with rated current 1200A, 1000A, 1500A. We send automatic machines AV2M-20SV, AV2M20S, AV2M20SV-56-43, AV2M20S-56-43, AV2M 20SV, AV2M 20S, AV2M-20SV, AV2M-20S, AV2M20SV-55-43-U3, AV2M20S-55-43-U3, AB2M20SB55-43-U3, AB2M20S55-43-U3, AB2M20SV5543UHL3, AB2M20S5543-UHL3 transport services or by self-pickup from Kharkov. Another name for this product is the AV2M-20C contactor and the AV2M-20CB contactor. Automatic switches AVM20SV and AVM20S are operated at substations of plants in Ukraine, Uzbekistan, Turkey, Moldova, Kazakhstan, Latvia, Estonia, Lithuania, Armenia, Georgia, Tajikistan, Azerbaijan, as well as in other countries of Europe and Asia! We export. It is advantageous to buy in Ukraine the switch AV2M - RPE RIMK.

Technical description on AB2M20S and AB2M20SV: Automatic switches AB2M20C are made with electromagnetic releasers and MRI releasers for overload tripping. Circuit breakers AB2M20S 2-pole are manufactured for direct current. Automatic switches AB2M20S 3-pole, manufactured for alternating current. AV2M20S - selective circuit breakers (with a time delay)

Automatic switches AB2M20SV5543 and AB2M20S5543 are designed to conduct current in normal mode and protect against overloads of unacceptable duration, during short circuits and unacceptable voltage drops, as well as for infrequent, up to 20 times a day, operational outages of electrical circuits with a nominal voltage up to 660 V AC frequencies of 50 and 60 Hz and up to 440 V DC. AC circuit breakers can also be used to protect infrequent direct starts of induction motors in the AC-3 application category. Circuit breakers are available with thermal and electromagnetic overcurrent releases, only with electromagnetic overcurrent releases and without overcurrent releases. Circuit breakers can be equipped with undervoltage release, shunt release, free contacts and electromagnetic drive. Automatic are available in fixed version - front, rear and combined connection and in retractable design.

Technical characteristics of AB2M-20S and AV2M-20SV switches:

1. Rated current 1500A.

2. Number of poles 2; 3

3. The rated currents of the releases for overload protection are up to 2000A.

4. Setpoint for the initial tripping current in the zone of overload currents, multiple of the rated current of the thermal release 1.25.

5. The wear resistance of switches - the total number of cycles BO 5000, the number of cycles BO under load 2000.

6. Weight - up to 126 kg.

Write a review

Note: HTML is not translated!
    Bad           Good

  • 129,828грн.

Tags: AV2M20SV, AV2M20S automatic switch, AVM, AV2M circuit breakers. AV2M-20SV, AV2M20S, AV2M20SV-56-43, AV2M20S-56-43, AV2M 20SV, AV2M 20S, AV2M-20SV, AV2M-20S, AV2M20SV-55-43-U3, AV2M20S-55-43-U3, AB2M20SB55-43-U3, AB2M20S55-43-U3, AB2M20SV5543UHL3, AB2M20S5543-UHL3