AV2M10SV, AV2M10S automatic switch

AV2M10SV, AV2M10S automatic switch

It is advantageous to buy in Ukraine automatic switches AB2M10SV-55-41-UHL3, AB2M10SV-56-41-UHL3 of withdrawable version and AB2M10S-55-41-UHL3 stationary for voltage of electrical circuits 380V, 500V for rated current 800A, 1000A, 630A, 500A, 750A. Send automatic circuit breakers AV2M10SV, AV2M10S, AV2M 10SV, AV2M10SV-56-41, AV2M10S-56-41, AV2M 10C AV2M10SV, AV2M10S, AV2M10SV55-41-U3, AV2M10S55-41-U3, U3-AV2M10SV55-41, AV2M10S55-41-U3, AB2M10SB5541UHL3, AB2M10S5541-UHL3 transport services or pickup from the city of Kharkov. Another name for this product is the AB2M-10C contactor and the AB2M-10CB contactor. Automatic switches AVM10SV and AVM10S are operated in substations of factories in Ukraine, Kazakhstan, Latvia, Estonia, Lithuania, Armenia, Georgia, Moldova, Uzbekistan, Turkey, Azerbaijan, Tajikistan, as well as in other countries of Europe and Asia! We export. LLC RPE RIMK

Technical description on AB2M10S and AB2M10SV: Automatic switches AB2M10C are manufactured with electromagnetic releasers and MRI releasers for overload tripping. Circuit breakers AB2M10S 2-pole are manufactured for direct current. Circuit breakers AB2M10S 3-pole, manufactured for alternating current. AB2M10S - selective circuit breakers (with a time delay)

Automatic switches AB2M10SV5541 and AB2M10S5541 are designed to conduct current in normal mode and protect against overloads of unacceptable duration, during short circuits and unacceptable voltage drops, as well as for infrequent, up to 20 times a day, operational outages of electric circuits with a nominal voltage up to 660 V AC frequencies of 50 and 60 Hz and up to 440 V DC. AC circuit breakers can also be used to protect infrequent direct starts of induction motors in the AC-3 application category. Circuit breakers are available with thermal and electromagnetic overcurrent releases, only with electromagnetic overcurrent releases and without overcurrent releases. Circuit breakers can be equipped with undervoltage release, shunt release, free contacts and electromagnetic drive. Automatic are available in fixed version - front, rear and combined connection and in retractable design.

Technical characteristics of AB2M-10S and AB2M-10SV switches:

1. Rated current 800A.

2. Number of poles 2; 3

3. The rated currents of the releases for overload protection are up to 1000A.

4. Setpoint for the initial tripping current in the zone of overload currents, multiple of the rated current of the thermal release 1.25.

5. The wear resistance of switches - the total number of cycles BO 5000, the number of cycles BO under load 2000.

6. Weight - up to 44 kg.

Write a review

Note: HTML is not translated!
    Bad           Good

  • 98,548грн.