circuit breakers А3711P
The manufacturer presents the A3711P circuit breaker - 160A, 150A, 80A, 40A, 25A - 440DC, 320DC, 220DC, 380AC, 400V, 660V 50-400Hz. Warranty up to 20 years. Appointment - for mobile installations. Supply of A3711P circuit breakers to any country in the world! The best price in Ukraine. In the USSR, automatic circuit breakers A3711P, A-3711P, A 3711 P, A 3711P, 3711P were widely used in Ukraine, Azerbaijan, Czech Republic, Moldova, Armenia, India, Uzbekistan, Mongolia, Vietnam, Estonia, Romania, Bulgaria, Poland, Vietnam, Iraq, Georgia, Algeria, Kazakhstan, Oman, Qatar as well as in the countries of near and far abroad. We manufacture A3711P automatics using the technology we have previously improved that was previously used at GP KhEMZ. Delivery. Export. EAC Certificate of Conformity No. EAEU KG417/033.UA02.00261 for the entire series of A3700 circuit breakers!
Technical description: Automatic circuit breakers A3711P for nominal current up to 160 A and VA3711P nom. current up to 200A with semiconductor, thermal and electromagnetic trips. Automatic switches A3711, ВА3711, ВА3713, ВА3715, ВА3717, А3713, А3715, А3717-2х pole are made on constant and variable (Hz 50, 400) currents. Automatic switches A3712, VA3712, VA3714, VA3716, VA3718, A3714, A3716, A3718-3x pole, are manufactured for alternating current (Hz 50, 400).
Automatic circuit breakers are designed for conducting the current in the normal mode and for protection during overloads of inadmissible duration, with short circuits and inadmissible voltage reductions, as well as for unexpected, up to 30 times a day, operative trips of electrical circuits with a nominal voltage up to 660 V AC of frequency 50 and 60 Hz and up to 440 VDC. AC circuit breakers can also be used for protection and emergency direct induction of asynchronous motors in the category of use of AC-3. The circuit-breakers are manufactured with semiconductor breakers, with semiconductor and electromagnetic maximum release, with thermal and electromagnetic maximum current trips, only with electromagnetic maximum trips of current and without the maximum release of current. The circuit-breakers can be equipped with a zero-voltage relay, an independent relay, free contacts and an electromagnetic actuator. The automatic switches are made in a stationary version - front, back and combined joints and in a sliding version.
Specifications of switches:
1. Rated current 160A, (VA3710 to 200A)
2. Number of poles 2
3. Nominal currents of thermal cut-offs 40A, 80А, 100А, 125А, 160А, semiconductor releasers 32А, 40А, 80А, 160А, 200А.
4 Setpoint for the current of electromagnetic maximum current trips up to 1600A.
5. Nominal working maximum breaking capacity, kA: at nominal voltage 380V AC 35 at nominal voltage 660V AC 20 at nominal voltage 440V DC 100.
6. Abrasion resistance of switches is the total number of cycles BO 16000, the number of cycles BO under the load of 10,000.
7. Overall dimensions (width х height х depth), 112х320х157 mm.
8. Mass (stationary version) 6.5 kg, electromagnetic drive 8.7 kg.