We produce and sell A3796P circuit breakers for 400A, 500A, 630A, 320A, 250A ~380V and ~660V 50Hz - 400Hz. Excellent quality and price in Ukraine for A-3796P breakers. Automatic switches A-3796P are used in diesel locomotives 2TE-116 and others. The warranty on automatic circuit breaker switch A 3796 P will be at least five years. When it was supplied by the GP KhEMZ, A3796P automatic circuit breakers in Ukraine, Moldova, Estonia, Latvia, Bulgaria, Hungary, Poland, Romania, South Korea, Armenia, Azerbaijan, Europe, Asia, Africa, South America, Sudan, Uzbekistan, USA, Tajikistan, Turkmenistan, Turkey, Serbia, Czech Republic, Vietnam, Slovenia, East Germany, India, Ethiopia, Mongolia, South Africa, Sri Lanka, Iraq, Algeria and Lithuania, proved themselves to be excellent. In stock. We export the breakers A-3796 P. EAC Certificate of Conformity No. EAEU KG417/033.UA02.00261 for the entire series of A3700 circuit breakers! Export
Technical Description switches A3790P: A3796 P circuit breakers are designed to conduct current in normal mode and to selectively protect against short circuits, overloads of unacceptable duration and unacceptable voltage drops, as well as for infrequent (up to 30 times a day) operational outages of electrical circuits with a rated voltage up 660 V AC frequency of 50 and 60 Hz.
Switches A3796P can be equipped with an independent release, free contacts and an electromagnetic actuator.
Switches are available in fixed version.
Technical characteristics of switches:
1. Rated current, A 630 (VA3790 to 800A)
2. Application category A.
3. The number of poles 3.
4. Rated current of a semiconductor release (PT), A 250; 320; 400; 500; 630.
5. Adjustable values of nominal operating currents IR, A -.
6. The initial current of operation in the zone of overload currents, a multiple of the nominal operating current of the RP -.
7. Setting the response time in the zone of overload currents at current -
8. The settings for the operation current in the area of short-circuit currents, multiples of the nominal operating current
9. Settings for the current operation of electromagnetic releases, A 4000 and 1200, 1400, 1600, 2000, 2500, 3200, 5000, 6300
10. Rated operating maximum breaking capacity, kA:
- with a rated voltage of 380 V 50.
- at a rated voltage of 660 V 27.
11. Wear resistance of switches:
- total number of cycles per 12000.
- the number of VO cycles under load 8000.
12. Overall dimensions (width x height x depth), mm 225x400x160.
13. Weight (stationary version), not more than 19.2 kg.
With electromagnetic drive 26.4 kg.