Circuit breaker A3795P
Production and sales of A3795P, A 3795P, A-3795P, A3795 P, A3795-P circuit breakers for rated currents 400A, 250A, 320A, 500A, 630A for ~380V and ~660V electrical networks 50Hz, 60Hz and 400Hz AC and =220V and =440V direct current (DC), with thermal and electromagnetic releasers from RPE RIMK LLC. The price in Ukraine for the new automatic circuit breaker A 3795P 400A 440DC 2P is the best! Warranty. Certificate. Export the automatic circuit breaker A 3795P 2P 400A. They are installed in the control cabinets of the chambers of diesel locomotives 2TE-116 and other mobile units. Automatic switches A 3795 P are widely used in factories in Ukraine, Estonia, Moldova, Latvia, Lithuania, India, Mongolia, Vietnam, South Korea, Romania, Hungary, Bulgaria, Armenia, Pakistan, Georgia, Algeria, Azerbaijan, Tajikistan, South Africa, Sri Lanka, Pakistan, Sudan, Egypt, Iraq, Qatar, Turkey, Ethiopia, Montenegro, Slovenia, Czech Republic, Poland and Slovakia, as well as countries of near and far abroad, in Asia, Europe, Africa, South America, the Middle East. Breakers A-3795P have proven themselves as trouble-free shut down. Sale, sell, selling the breakers A3795P.
Technical Description circuit breakers A 3790P: A3795P circuit breakers are designed to conduct current in normal mode and to selectively protect against short circuits, overloads of unacceptable duration and unacceptable voltage drops, as well as for infrequent (up to 30 times a day) operational outages of electric circuits with rated voltage = 440V and up to 660 V AC frequencies of 50 and 60 Hz.
The switches can be equipped with an independent release, free contacts and an electromagnetic drive.
Switches are available in fixed and retractable versions.
Technical characteristics of switches:
1. Rated current, A 630
2. Utilization category A.
3. Number of poles 2.
4. Rated current of the semiconductor release (RT), A 250; 320; 400; 500; 630.
5. Setting for the operation time in the zone of overload currents at a current of 1.4 In
6. Settings for the current of operation of electromagnetic releases, A 1400; 2000; 2400; 3800; 4000; 4200; 5000; 6300.
7. Rated operating maximum breaking capacity, kA:
- at rated voltage 440 V 50.
- at rated voltage 660 V 27.
8. Wear resistance of switches:
- total number of VO cycles 12000.
- number of VO cycles under load 8000.
9. Overall dimensions (width x height x depth), mm 225x400x160.
10. Weight (manual drive), no more than 15.6 kg. No more
With electromagnetic drive 20.8 kg.