Circuit breaker A3334
I will sell automatic switches A3334, A-3334, A3334M, for 100A, 120A, 150A, 180A, 200A, 220A for the voltage of electric networks 220V, 380V, 400V, 500V with a frequency of 50-60 hertz and 400 Hz. The price in Ukraine and in other countries of the world for the new A 3334 and A3333 circuit breakers is our best! Always in stock new A3334 switches, ready for sale, with any set of assembly units and a set of clamps. A huge number of automatic circuit breakers A3334 produced by RPE RIMK, HEMZ is used at enterprises in Belarus, Russia, Moldova, Latvia, Estonia, Lithuania, India, Mongolia, Vietnam, Korea, Romania, Hungary, Bulgaria, Armenia, Azerbaijan, Belarus, Moldova, South Africa , Sudan, Egypt and Kazakhstan, Uzbekistan as well as in the countries of near and far abroad, in Asia, Europe, Africa, South America, the Middle East. A3334 and A3333 automatic storage machines are on sale in the cities of Kharkov, Kiev, Dnipro, Zaporizhia, Astana, Moscow, St. Petersburg, Vladivostok, Krasnoyarsk, Novosibirsk, Perm, Chelyabinsk, Ufa, Irkutsk, Chita, Yuzhno-Sakhalinsk, Nizhny Novgorod, Naberezhnye Chelny, Kazan, Tyumen, Tallinn, Vilnius, Riga, Omsk, Voronezh, Yekaterinburg, Murmansk, Kherson, Nikolaev, Minsk, Novorossiysk, Magadan, Kaliningrad, Belgorod, Petropavlovsk-Kamchatsky, Chelyabinsk, Rostov-on-Don, Khabarovsk, Saratov , Volgograd, Nakhodka, Saratov, Komsomolsk-on-Amur, Samara, Ufa and others GIH cities of the CIS. But the new auto off A3334 can only be purchased from RPE RIMK or our dealers. The warranty on the A3334 switch is 15 years! Sales to any country in the world!
Technical description: Circuit-breakers A3334 for rated current up to 200 A with electromagnetic releases and electromag-thermal releases. Automatic switches A3334 3-pole, are made on an alternating current.
Automatic switches A3334 are designed to conduct current in normal mode and protect against overloads of unacceptable duration, with short circuits and unacceptable voltage drops, as well as for infrequent, up to 20 times a day, operational disconnections of electrical circuits with a rated voltage of up to 660 V AC frequency 50 and 60 Hz and up to 440 VDC. AC automatic circuit breakers can also be used for protection and infrequent direct starts of asynchronous motors in the application category of AC-3. Circuit-breakers are produced by thermal and electromagnetic maximum releases, only with electromagnetic maximum current releases and without maximum current releases. The circuit breakers can be equipped with an independent release, free contacts and an electromagnetic drive. Automatic are produced in stationary version - with front, rear and combined connection.
The A3334 M switches are used for installation on ships with an unrestricted area of navigation and can be operated under the following conditions:
a) ambient air pressure in the range from 8000 to 16000 mm of water column;
b) ambient air temperature from minus 40ºС (without dropping of dew and frost at temperatures from minus 40ºС to 5ºС) to 50ºС. It is sometimes permissible (5-7 times for the whole service life of the switch) to raise the temperature to 60 ° C for a period of about 2 hours;
c) the relative humidity of the ambient air is not more than 98% at a temperature of 40 ° C;
d) the location of the switch - protected from water, oil, emulsion, etc .;
e) environment - non-explosive, free of dust (including conductive) in an amount that disrupts the operation of the switch, aggressive gases and vapors in concentrations that destroy metals and insulation;
e) the absence of direct exposure to solar and penetrating radiation, which disrupts the thermal balance of the circuit breaker and leads to aging of the insulation.
Technical characteristics of switches A-3334:
1. Rated current up to 200A.
2. Number of poles 3.
3. Rated currents of thermal releases of 100-220A.
4. Setting for the initial pick-up current in the zone of the overload currents, multiples of the rated current of the thermal trip unit 1.3.
5. Settings for the current of operation of electromagnetic maximum current releases up to 2000A.
6. Rated operating short-circuit breaking capacity, kA: at a rated voltage of 380 V AC 25, at a nominal voltage of 660 V AC 19, at a nominal voltage of 440 VDC 50.
7. Wear resistance of circuit breakers - total number of cycles of VO 3000, number of VO cycles under load 1500.
8. Weight (stationary version) - 10.0
